1.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): 144-152, Mar-Abr. 2023. ilus, tab, graf
Artículo en Inglés | IBECS | ID: ibc-217116

RESUMEN

Background: Calcaneal fractures can be high energy intra-articular injuries associated with joint depression. Challenges to fracture reduction include lateral wall blow out, medial wall overlap, comminution and central bone loss. Secondary deformity such as hindfoot varus alters foot biomechanics. Minimally invasive approaches with indirect reduction of the calcaneal tuberosity to maintain the reduction using posterior screws is routinely being used in the treatment of joint depression fractures. Biomechanically, optimum screw numbers and configuration is not known. Biomechanical studies have evaluated and proposed different screw configurations, however, it is not clear which configuration best controls varus deformity. This study aims to determine the optimum screw configuration to control varus deformity in Sanders 2B calcaneal fractures. Methods: Sawbone models were prepared to replicate Sanders type 2-B fracture, with central bone loss and comminution. 0.5cm medial wedge of the calcaneal tuberosity was removed to create varus instability. After stabilising posterior facet with a single 4mm partial threaded screw, and applied an 8 hole contoured plate to stabilise the angle of Gissane, inserted one or two 7mm cannulated partially threaded Charlotte™ (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) Headless Multi-use Compression (under image guidance) extra screws to control varus and subsidence deformity of the fracture. Coronal plane displacement of the dissociated calcaneal tuberosity fragment relative to the body when applying 5N, 10N and 20N force was measured in millimetres (mm). Results: 2 screws inserted (one medial screw into the sustentaculum talus from inferior to superior and, one lateral screw into the long axis anterior process) provides the least displacement (0.88±0.390 at 5N and 1.7±1.251 at 20N) and the most stable construct (p<0.05) when compared to other configurations...(AU)


Introducción: Las fracturas de calcáneo suelen ser lesiones intraarticulares de alta energía asociadas con hundimiento articular. Además, se añade con frecuencia el estallido de la pared lateral, la superposición de la pared medial, la conminución y la pérdida de hueso bajo la carilla articular. La deformidad secundaria, como el varo del retropié, altera la biomecánica del pie. Nuestra comunidad utiliza cada vez más abordajes mínimamente invasivos con reducción indirecta de la tuberosidad del calcáneo para mantener la reducción mediante tornillos posteriores. Hay estudios que proponen diferentes configuraciones de tornillos, tras experimentación biomecánica, pero aún no es bien conocido qué configuración controla mejor la deformidad en varo. Este estudio tiene como objetivo determinar la configuración óptima del tornillo para controlar la deformidad en varo en las fracturas de calcáneo Sanders 2B. Método: Se prepararon modelos en Sawbone para replicar la fractura de Sanders tipo 2B, con pérdida de hueso central y con conminución. Se eliminó una cuña medial de 0,5cm de la tuberosidad calcánea para crear inestabilidad en varo. Tras estabilizar el ángulo de Gissane con un tornillo aislado parcialmente roscado de 4mm y una placa moldeada, se utilizaron tornillos de compresión multiuso Charlotte (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) sin cabeza, canulados y parcialmente roscados de 7mm insertados sobre una AK bajo escopia. El desplazamiento del plano sagital del fragmento de tuberosidad fracturado en comparación con el cuerpo al aplicar una fuerza de 5N, 10N y 20N se midió en milímetros (mm). Resultados: Dos tornillos insertados (un tornillo medial en el sustenaculum tali de inferior a superior y un tornillo lateral en el eje largo del astrágalo) proporciona el menor desplazamiento (0,88±0,390 a 5N y 1,7±1,251 a 20N) y resulta la construcción más estable (p<0,05) en comparación con otras configuraciones...(AU)


Asunto(s)
Humanos , Tornillos Óseos , Calcáneo/lesiones , Talón/cirugía , Fenómenos Biomecánicos , Ortopedia
2.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): T144-T15, Mar-Abr. 2023. ilus, tab, graf
Artículo en Español | IBECS | ID: ibc-217117

RESUMEN

Background: Calcaneal fractures can be high energy intra-articular injuries associated with joint depression. Challenges to fracture reduction include lateral wall blow out, medial wall overlap, comminution and central bone loss. Secondary deformity such as hindfoot varus alters foot biomechanics. Minimally invasive approaches with indirect reduction of the calcaneal tuberosity to maintain the reduction using posterior screws is routinely being used in the treatment of joint depression fractures. Biomechanically, optimum screw numbers and configuration is not known. Biomechanical studies have evaluated and proposed different screw configurations, however, it is not clear which configuration best controls varus deformity. This study aims to determine the optimum screw configuration to control varus deformity in Sanders 2B calcaneal fractures. Methods: Sawbone models were prepared to replicate Sanders type 2-B fracture, with central bone loss and comminution. 0.5cm medial wedge of the calcaneal tuberosity was removed to create varus instability. After stabilising posterior facet with a single 4mm partial threaded screw, and applied an 8 hole contoured plate to stabilise the angle of Gissane, inserted one or two 7mm cannulated partially threaded Charlotte™ (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) Headless Multi-use Compression (under image guidance) extra screws to control varus and subsidence deformity of the fracture. Coronal plane displacement of the dissociated calcaneal tuberosity fragment relative to the body when applying 5N, 10N and 20N force was measured in millimetres (mm). Results: 2 screws inserted (one medial screw into the sustentaculum talus from inferior to superior and, one lateral screw into the long axis anterior process) provides the least displacement (0.88±0.390 at 5N and 1.7±1.251 at 20N) and the most stable construct (p<0.05) when compared to other configurations...(AU)


Introducción: Las fracturas de calcáneo suelen ser lesiones intraarticulares de alta energía asociadas con hundimiento articular. Además, se añade con frecuencia el estallido de la pared lateral, la superposición de la pared medial, la conminución y la pérdida de hueso bajo la carilla articular. La deformidad secundaria, como el varo del retropié, altera la biomecánica del pie. Nuestra comunidad utiliza cada vez más abordajes mínimamente invasivos con reducción indirecta de la tuberosidad del calcáneo para mantener la reducción mediante tornillos posteriores. Hay estudios que proponen diferentes configuraciones de tornillos, tras experimentación biomecánica, pero aún no es bien conocido qué configuración controla mejor la deformidad en varo. Este estudio tiene como objetivo determinar la configuración óptima del tornillo para controlar la deformidad en varo en las fracturas de calcáneo Sanders 2B. Método: Se prepararon modelos en Sawbone para replicar la fractura de Sanders tipo 2B, con pérdida de hueso central y con conminución. Se eliminó una cuña medial de 0,5cm de la tuberosidad calcánea para crear inestabilidad en varo. Tras estabilizar el ángulo de Gissane con un tornillo aislado parcialmente roscado de 4mm y una placa moldeada, se utilizaron tornillos de compresión multiuso Charlotte (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) sin cabeza, canulados y parcialmente roscados de 7mm insertados sobre una AK bajo escopia. El desplazamiento del plano sagital del fragmento de tuberosidad fracturado en comparación con el cuerpo al aplicar una fuerza de 5N, 10N y 20N se midió en milímetros (mm). Resultados: Dos tornillos insertados (un tornillo medial en el sustenaculum tali de inferior a superior y un tornillo lateral en el eje largo del astrágalo) proporciona el menor desplazamiento (0,88±0,390 a 5N y 1,7±1,251 a 20N) y resulta la construcción más estable (p<0,05) en comparación con otras configuraciones...(AU)


Asunto(s)
Humanos , Tornillos Óseos , Calcáneo/lesiones , Talón/cirugía , Fenómenos Biomecánicos , Ortopedia
3.
Rev Esp Cir Ortop Traumatol ; 67(2): 144-152, 2023.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35809779

RESUMEN

BACKGROUND: Calcaneal fractures can be high energy intra-articular injuries associated with joint depression. Challenges to fracture reduction include lateral wall blow out, medial wall overlap, comminution and central bone loss. Secondary deformity such as hindfoot varus alters foot biomechanics. Minimally invasive approaches with indirect reduction of the calcaneal tuberosity to maintain the reduction using posterior screws is routinely being used in the treatment of joint depression fractures. Biomechanically, optimum screw numbers and configuration is not known. Biomechanical studies have evaluated and proposed different screw configurations, however, it is not clear which configuration best controls varus deformity. This study aims to determine the optimum screw configuration to control varus deformity in Sanders 2B calcaneal fractures. METHODS: Sawbone models were prepared to replicate Sanders type 2-B fracture, with central bone loss and comminution. 0.5cm medial wedge of the calcaneal tuberosity was removed to create varus instability. After stabilising posterior facet with a single 4mm partial threaded screw, and applied an 8 hole contoured plate to stabilise the angle of Gissane, inserted one or two 7mm cannulated partially threaded Charlotte™ (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) Headless Multi-use Compression (under image guidance) extra screws to control varus and subsidence deformity of the fracture. Coronal plane displacement of the dissociated calcaneal tuberosity fragment relative to the body when applying 5N, 10N and 20N force was measured in millimetres (mm). RESULTS: 2 screws inserted (one medial screw into the sustentaculum talus from inferior to superior and, one lateral screw into the long axis anterior process) provides the least displacement (0.88±0.390 at 5N and 1.7±1.251 at 20N) and the most stable construct (p<0.05) when compared to other configurations. A single medial screw into the sustentaculum tali (conf. 3) resulted in the least stable construct and most displacement (4.04±0.971 at 5N and 11.24±7.590 at 20N) (p<0.05). CONCLUSION: This study demonstrates the optimal screw configuration to resist varus in calcaneal fractures using minimally invasive techniques. Optimal stability is achieved using 2 screws; one located along the long axis of the calcaneus (varus control) and the other placed in the short axis directed towards the posterior facet of the calcaneus (control varus and subsidence). Further cadaver research would help evaluate optimal screw placement in simulated fractures to further assess reproducibility.


Asunto(s)
Traumatismos del Tobillo , Traumatismos de los Pies , Fracturas Óseas , Fracturas Conminutas , Hallux Varus , Traumatismos de la Rodilla , Humanos , Fijación Interna de Fracturas/métodos , Reproducibilidad de los Resultados , Pie , Tornillos Óseos
4.
Rev Esp Cir Ortop Traumatol ; 67(2): T144-T152, 2023.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36528297

RESUMEN

BACKGROUND: Calcaneal fractures can be high energy intra-articular injuries associated with joint depression. Challenges to fracture reduction include lateral wall blow out, medial wall overlap, comminution and central bone loss. Secondary deformity such as hindfoot varus alters foot biomechanics. Minimally invasive approaches with indirect reduction of the calcaneal tuberosity to maintain the reduction using posterior screws is routinely being used in the treatment of joint depression fractures. Biomechanically, optimum screw numbers and configuration is not known. Biomechanical studies have evaluated and proposed different screw configurations, however, it is not clear which configuration best controls varus deformity. This study aims to determine the optimum screw configuration to control varus deformity in Sanders 2B calcaneal fractures. METHODS: Sawbone models were prepared to replicate Sanders type 2-B fracture, with central bone loss and comminution. 0.5 cm medial wedge of the calcaneal tuberosity was removed to create varus instability. After stabilising posterior facet with a single 4 mm partial threaded screw, and applied an 8 hole contoured plate to stabilise the angle of Gissane, inserted one or two 7 mm cannulated partially threaded CharlotteTM (Wright Medical Technology, Memphis, USA) Headless Multi-use Compression (under image guidance) extra screws to control varus and subsidence deformity of the fracture. Coronal plane displacement of the dissociated calcaneal tuberosity fragment relative to the body when applying 5 N, 10 N and 20 N force was measured in millimetres (mm). RESULTS: 2 screws inserted (one medial screw into the sustentaculum talus from inferior to superior and, one lateral screw into the long axis anterior process) provides the least displacement (0.88 ± 0.390 at 5 N and 1.7 ± 1.251 at 20 N) and the most stable construct (p < 0.05) when compared to other configurations. A single medial screw into the sustentaculum tali (conf. 3) resulted in the least stable construct and most displacement (4.04 ± 0.971 at 5 N and 11.24 ± 7.590 at 20 N) (p < 0.05). CONCLUSION: This study demonstrates the optimal screw configuration to resist varus in calcaneal fractures using minimally invasive techniques. Optimal stability is achieved using 2 screws; one located along the long axis of the calcaneus (varus control) and the other placed in the short axis directed towards the posterior facet of the calcaneus (control varus and subsidence). Further cadaver research would help evaluate optimal screw placement in simulated fractures to further assess reproducibility.


Asunto(s)
Traumatismos del Tobillo , Traumatismos de los Pies , Fracturas Óseas , Fracturas Conminutas , Traumatismos de la Rodilla , Humanos , Fijación Interna de Fracturas/métodos , Reproducibilidad de los Resultados , Pie , Tornillos Óseos
5.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 59(1): 26-35, ene.-feb. 2015. tab, ilus
Artículo en Español | IBECS | ID: ibc-132375

RESUMEN

Objetivo. El propósito de este estudio es valorar la necesidad de bloquear distalmente los clavos Gamma 3 (Stryker. Mahwah, New Jersey. USA) en fracturas pertrocantéreas de fémur 31-A1 y 31-A2 de la AO. Material y métodos. Desde junio de 2011 hasta enero de 2013 se recoge una muestra formada por 177 pacientes con fractura pertrocantérea de fémur tratados en nuestro centro mediante osteosíntesis con clavo Gamma 3 estándar. Es un estudio prospectivo y aleatorizado según el año de nacimiento de cada paciente, par con bloqueo o impar sin bloqueo distal del clavo, formando dos grupos de 90 y 87 fracturas respectivamente. Resultados. En los pacientes intervenidos mediante clavo con bloqueo distal se observó una mayor incidencia de complicaciones médicas, una menor incidencia de complicaciones biomecánicas y un aumento en el colapso del foco de fractura en comparación con el grupo control, siendo estas diferencias estadísticamente significativas (p < 0,05). También se observa en el grupo con bloqueo distal un mayor requerimiento transfusional y una mayor tasa de éxitus presentando diferencias estadísticamente significativas (p < 0,05), sin embargo esta significación desaparece al ajustar los resultados por otras características relacionadas con los pacientes. Conclusiones. Basándonos en los resultados hallados en este trabajo, el uso del tornillo de bloqueo distal en los clavos Gamma 3 debe restringirse a fracturas pertrocantéreas inestables tras reducción donde se requiera una estabilidad adicional al clavo intramedular, pudiendo así disminuir el riesgo de complicaciones derivadas de su uso (AU)


Objective. The purpose of this study is to assess the need to lock the Gamma 3 nail (Stryker, Mahwah New Jersey USA) distally for intertrochanteric fractures of femur 31-A1 and 31-A2 of the AO. Material and methods. Details were recorded on a sample of 177 patients with intertrochanteric femoral fractures treated in our hospital by a standard Gamma nail between June 2011 and January 2013. A prospective study was conducted by randomizing patients by year of birth, even numbers with, or odd number without, distal locking, forming two groups of 90 and 87 fractures, respectively. Results. The patients treated with a distal locking nail had an increased incidence of medical complications, a lower incidence of biomechanical complications, and an increase in the fracture collapse compared with the control group, with statistical significance (p < 0 .05). It is also observed in the group with distal locking increased transfusion requirement and a higher death rate, with statistically significant differences (p < 0 .05), but this significance disappears when adjusting for other patient-related characteristics. Conclusions. Based on the results found in this work, the use of distal locking screw in the Gamma 3 nails should be restricted to unstable trochanteric fractures after reduction where additional stability to the intramedullary nail is required, and may decrease the risk of complications from use (AU)


Asunto(s)
Humanos , Masculino , Femenino , Anciano de 80 o más Años , Fracturas de Cadera/diagnóstico , Fracturas de Cadera/cirugía , Fracturas de Cadera , Clavos Ortopédicos/tendencias , Clavos Ortopédicos , Procedimientos Ortopédicos/métodos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/tendencias , Estudios Prospectivos , Fracturas del Fémur/cirugía , Estudios de Cohortes , Procedimientos Ortopédicos , Lesiones de la Cadera
6.
Rev Esp Cir Ortop Traumatol ; 59(1): 26-35, 2015.
Artículo en Español | MEDLINE | ID: mdl-25088240

RESUMEN

OBJECTIVE: The purpose of this study is to assess the need to lock the Gamma 3 nail (Stryker, Mahwah New Jersey USA) distally for intertrochanteric fractures of femur 31-A1 and 31-A2 of the AO. MATERIAL AND METHODS: Details were recorded on a sample of 177 patients with intertrochanteric femoral fractures treated in our hospital by a standard Gamma nail between June 2011 and January 2013. A prospective study was conducted by randomizing patients by year of birth, even numbers with, or odd number without, distal locking, forming two groups of 90 and 87 fractures, respectively. RESULTS: The patients treated with a distal locking nail had an increased incidence of medical complications, a lower incidence of biomechanical complications, and an increase in the fracture collapse compared with the control group, with statistical significance (p < 0.05). It is also observed in the group with distal locking increased transfusion requirement and a higher death rate, with statistically significant differences (p < 0.05), but this significance disappears when adjusting for other patient-related characteristics. CONCLUSIONS: Based on the results found in this work, the use of distal locking screw in the Gamma 3 nails should be restricted to unstable trochanteric fractures after reduction where additional stability to the intramedullary nail is required, and may decrease the risk of complications from use.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas/métodos , Fracturas de Cadera/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Fijación Intramedular de Fracturas/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
7.
Patol. apar. locomot. Fund. Mapfre Med ; 3(4): 242-259, oct.-dic. 2005. ilus
Artículo en Es | IBECS | ID: ibc-047487

RESUMEN

Las prótesis totales de rodilla constituyen uno de los implantesmás colocados en el ámbito de la ortopedia. El númerode modelos existentes en el mercado es muy elevadoy todos tienen sus características. A pesar de ello podemosagrupar las artroplastias de rodilla por estas caracterísricas,siendo las prótesis de platillo móvil el grupo más novedoso.Revisamos la bibliogrfía más reciente sobre la biomecánicade las prótesis totales de rodilla, englobando aspectos comolos materiales, el polietileno, la fijación, la geometría ola presencia del ligamento cruzado posterior para entenderen profundidad el funcionemiento de una PTR


Total knee prostheses (TKAs) are one of the most frequentimplants we use like orthpaedists. There are a largenumber of models and all of them have their characteristics.Despite of it we can group TKAs in avery few ones inwhich mobile-bearing arthroplasty in the newness. We reviewthe literature about biomechanics of TKAs includingmaterials, UHMWPE, fixation of the prostheses, geometryor presence of the cruciate posterior ligament to really understandarthroplasty working


Asunto(s)
Humanos , Fenómenos Biomecánicos/métodos , Prótesis de la Rodilla/clasificación , Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla/cirugía
8.
Patol. apar. locomot. Fund. Mapfre Med ; 3(3): 189-200, jul.-sept. 2005. ilus
Artículo en Es | IBECS | ID: ibc-047481

RESUMEN

La biomecánica de la rodilla todavía no se conoce exactamente.Diversos patrones se han establecido, pero ningunoha alcanzado el funcionamiento real de la articulación.Revisamos la bibliografía y presentamos la evolucióndel entendimiento del movimiento de la rodilla hasta llegaral modelo de seis grados de libertad en la zona patelofemoraly en la tibiofemoral. Este modelo parece ser el másaproximado a la realidad en cuanto a la cinemática de larodilla


Knee´s biomechanics is not well known yet. A largenumber of patterns has been stablished, but neither ofthem has reached the right articular movement. We reviewthe literature and present the understanding about kneemovement until six grades of freedom model in patello-femoraland tibio-femoral zones. This model seems to be themost approximate to reality in knee kinematics


Asunto(s)
Humanos , Fenómenos Biomecánicos , Articulación de la Rodilla/fisiología , Cinésica , Rodilla/fisiología , Rótula/fisiología , Fémur/fisiología , Cartílago Articular/fisiología